Seven standards.
One dimension table.

A DN50 pipe is 63 mm outside in China, 60 mm in Japan, and 60.32 mm under ASTM. Those are not the same pipe, and the fittings do not cross over. This is the table we quote from — the one most catalogues leave out.

Systems7
RangeDN10 – DN500
BasisOD × wall thickness
SourceOur QC files
01 / The problem

One nominal size,
five real pipes

Take the pipe everyone calls “2 inch”. It is five different products depending on which standard the client wrote into the schedule — and only two of them are interchangeable.

Standard Wall thickness OD × wall
GBChina 63 × 6.0
CNSTaiwan, China 60 × 4.1
JISJapan 60 × 4.5
ASTM SCH40US 60.32 × 4.165
ASTM SCH80US 60.32 × 5.87
!
Wall thickness moves 43% across the same nominal size

From 4.1 mm (CNS) to 5.87 mm (SCH80) on a “2-inch” pipe. Order the wrong one and the pressure rating, the cost per metre and the fittings are all wrong with it.

02 / Dimension matrix

DN10 to DN500,
side by side

Outside diameter and wall thickness with the tolerance each standard actually specifies. Where a standard does not list a size, we show a dash rather than an estimate.

DN Inch GBChina CNSTaiwan, China JISJapan NPS / BSUS / UK ASTM SCH40Wall series ASTM SCH80Wall series
mm OD × WT OD × WT OD × WT OD OD × WT OD × WT
103/8"16182.2±0.6182.5±0.217.14——
151/2"202.0±0.4222.7±0.6223.0±0.321.3421.33.025±0.25521.33.985±0.255
203/4"253.0±0.5262.7±0.6263.0±0.326.6726.73.125±0.25526.74.165±0.255
251"324.0±0.6343.2±0.6323.5±0.333.433.43.635±0.25533.44.815±0.265
321+1/4"404.6±0.7423.2±0.6383.5±0.342.1642.163.815±0.25542.165.14±0.29
401+1/2"505.3±0.8483.6±0.8484.0±0.448.2648.263.94±0.2548.265.385±0.305
502"636.0±0.9604.1±0.8604.5±0.460.3260.324.165±0.25560.325.87±0.33
652+1/2"756.6±1.0764.1±0.8764.5±0.473.0273.025.465±0.30573.027.43±0.42
803"907.3±1.1895.1±0.8895.9±0.488.988.95.82±0.3388.98.075±0.455
1004"1108.0±1.21146.6±1.01147.1±0.5114.3114.36.375±0.355114.39.07±0.51
1255"1409.3±1.41407.5±1.21407.5±0.5141.3——
1506"16010±1.51658.5±1.41659.6±0.7168.28168.37.54±0.43168.311.63±0.66
2008"22512±1.821610.5±1.421611.0±0.7219.08219.18.675±0.495219.113.46±0.76
25010"25012.6±1.926713.0±1.826713.6±0.9273.05273.19.83±0.56273.115.96±0.9
30012"31514±2.131815.5±2.231816.2±1.1323.85323.910.93±0.62323.918.49±1.04
35014"—37018.0±2.6————
40016"—42020.5±3.0————
45018"—47022.9±3.4————
50020"—52025.3±3.8————

All dimensions in millimetres. Tolerance shown as specified by the standard, not as a manufacturing allowance. Blank cells are sizes the standard does not cover.

03 / The conversion trap

PN is not SCH.
They do not convert.

A PN16 pipe is not “the same as” SCH80, and a buyer who treats them as interchangeable will fail the pressure test — or pay for wall thickness the service never needed.

PN and Class describe a pressure rating at a reference temperature. They are a performance claim: this pipe holds 16 bar at 20 °C.

SCH40 and SCH80 describe a wall-thickness series inherited from steel pipe. They are a geometry, not a rating — the pressure a SCH80 PVC pipe actually holds depends on the resin, the temperature and the safety factor applied.

So we quote in the system your schedule names, and state the rating in that system's own terms. If your client's document says SCH80 and your supplier's says PN16, those two documents cannot be compared without a calculation — and we do that calculation before the order, not after.

Reference PVC pipe dimension reference
04 / Where orders go wrong

Four mismatches we check
before quoting

01

Pipe to fitting

A GB 63 mm pipe will not take a JIS 60 mm socket. Where the schedule mixes systems, we flag it before the PO.

02

Pipe to flange

GB/T and ASME B16.5 flanges differ in bolt circle and hole count at the same nominal size. Bolting one to the other does not seal.

03

Rating to temperature

PVC derates sharply above 25 °C. A PN16 line at 45 °C is not a PN16 line, and we derate the quote accordingly.

04

Standard to test pressure

Each system sets its own site-test pressure. We state which one the certificate will be issued against.

Send the schedule. We will read it against the standard.

Any size from DN10 to DN500 in GB, CNS, JIS, NPS/BS, ASTM SCH40 or SCH80 — quoted in the system your document names.