Applications
Six duty points, six different answers. Each block states the system we recommend, the pressure class that usually applies and the jointing method that survives site conditions — the copy that turns a search into an enquiry.
01 · Municipal water supply
Distribution mains and service connections.
02 · Building services
Hot & cold risers, heating, compressed air.
03 · Drainage & sewerage
Soil, waste, rainwater, gravity sewers.
04 · Agriculture
Field networks, drip and sprinkler mains.
05 · Industrial service
Chemical, cooling water, effluent.
06 · Infrastructure
Dewatering, ducting, site services.

Strung out for stringing
Grey PVC pressure pipe laid along the trench line before jointing.

Loading to the loading plan
Large-bore PVC bundled and blocked for a 40 ft container or flatbed.

Fittings to match
Socket, threaded and flanged fittings in the same compound as the pipe.
Municipal water
supply
Distribution mains, branch lines and service connections in buried or above-ground service. The selection driver is pressure class against surge, not nominal pressure.
| Element | Specification |
|---|---|
| Trunk main | PE 100, SDR 11 – 17, butt fusion |
| Distribution branch | PVC-U, PN 10 – 16, rubber ring or solvent weld |
| Service connection | PE 100 coil, compression or electrofusion |
| Valve / hydrant joints | Flanged spigot, PVC–metal transition |
| Test criteria | Hydrostatic at 1.5 × design pressure, 1 h hold at 20 °C |
Building
services
Inside the building the constraint changes: temperature, riser height and fire compartment penetration decide the material. PPR usually wins the hot side; PVC-U or PE takes the cold and the drainage.
| Element | Specification |
|---|---|
| Hot water riser | PPR, SDR 6 – 7.4 (PN 20 – 16), socket fusion |
| Cold water riser | PPR or PVC-U, PN 10 – 16 |
| Heating circuit | PPR with fibre reinforcement (low expansion) |
| Compressed air | PPR, PN 10, fusion jointed |
| Insulation / support | Spacing per diameter; expansion loops at risers |
Drainage &
sewerage
Gravity systems live or die on slope and joint integrity. Rubber-ring sockets tolerate ground movement better than solvent weld in trench conditions.
| Element | Specification |
|---|---|
| Soil & waste | PVC-U, SN 4 / SN 8 ring stiffness |
| Rainwater downpipe | PVC-U, solvent weld, UV-stabilised |
| Gravity sewer | PVC-U or PE, rubber ring / fusion |
| Inspection | Access fittings, rodding eyes, inspection chambers |
| Bedding | Sand or selected fill per project specification |
Agriculture
& irrigation
Long runs, low pressure, sunlight and rough handling. PE coil in the field, PVC-U for the fixed headworks and risers.
| Element | Specification |
|---|---|
| Field main | PE 100 coil, SDR 21 – 26, compression fittings |
| Sub-main | PVC-U, PN 6 – 10, solvent weld |
| Riser / hydrant | PVC-U or PE, threaded transition |
| Greenhouse | PPR or PE, low-pressure drip network |
| UV exposure | Carbon black content ≥ 2 % for above-ground PE |
Industrial
service
Chemical resistance is a table, not an opinion — concentration and temperature decide whether PVC-U, CPVC or PE is acceptable. We check the medium before quoting.
| Element | Specification |
|---|---|
| Cooling water | PVC-U or PE, PN 10 |
| Dilute acid / alkali | PVC-U or CPVC depending on temperature |
| Effluent | PE or PVC-U, fusion / solvent weld |
| Slurry | PE, thick wall, flanged at equipment |
| Documentation | Chemical resistance chart per medium, on request |
Infrastructure
& mining
Temporary and permanent lines where pipe gets moved, dragged and re-laid. Toughness matters more than pressure rating.
| Element | Specification |
|---|---|
| Dewatering | PE 100, SDR 17 – 21, quick couplings |
| Slurry / tailings | PE, thick wall, flanged or fused |
| Cable ducting | PVC-U or PE conduit, buried |
| Site water | PE coil, compression fittings |
| Repair | Full-seal repair clamps, couplers |
Tell us the duty point
Medium, flow, pressure, temperature, installation method. We come back with the system, the pressure class and a price.