Overview
PVC-C is PVC-U with roughly two thirds of its hydrogen replaced by chlorine. The bigger, heavier chlorine atom stiffens the chain, so the pipe keeps its strength at temperatures where PVC-U has already gone soft — and it holds up against oxidising chemicals such as sodium hypochlorite that attack ordinary PVC.
It is not a cheaper PVC-U and should not be sold as one. It costs more per metre, is stiffer and more notch-sensitive in cold weather, and needs its own cement. Where it pays: hot service, chlorine, and cable ducting in corrosive ground.
Dimensions — Schedule 80
Sizes we hold production records for. Outside diameter to the ASTM IPS series, wall to Schedule 80. Schedule 40 and 5″–12″ are quoted to order.
| Nominal size | Outside diameter | Wall thickness |
|---|---|---|
| 1/2″ | 21.34 | 3.73 |
| 3/4″ | 26.67 | 3.91 |
| 1″ | 33.40 | 4.55 |
| 1-1/4″ | 42.16 | 4.85 |
| 1-1/2″ | 48.26 | 5.08 |
| 2″ | 60.32 | 5.54 |
| 2-1/2″ | 72.90 | 7.01 |
| 3″ | 88.90 | 7.62 |
| 4″ | 114.30 | 8.56 |
Pressure rating of a CPVC line is not a single number: it derates with temperature and with the chemical in the line. Send us the medium, the concentration and the working temperature and we will quote against the derating curve rather than against the 23 °C figure.
PVC-C against PVC-U, where it matters
| Property | PVC-U | PVC-C / CPVC |
|---|---|---|
| Continuous service temperature | up to 45 °C | up to 95 °C |
| Hot water under pressure | Not suitable | Standard duty |
| Oxidising chemicals hypochlorite, chlorine solution | Attacked at strength | Preferred material |
| Dilute acids & alkalis | Good | Good, wider concentration band |
| Impact at low ambient | Brittle below 0 °C | Brittle, handles with more care |
| Solvent cement | PVC-U cement | CPVC cement — not interchangeable |
| Relative cost, same size | 1.0 | Higher — priced per project |
Where it is specified
Hot water & process lines
Plant hot water, tempered process water, CIP and wash-down lines where a metal system would corrode and PVC-U would sag.
Chlorine & hypochlorite dosing
Disinfection dosing skids, sodium hypochlorite storage and transfer — the duty that most often destroys a PVC-U line within a season.
Cable ducting
Power and instrumentation ducts in corrosive soil or at plant boundaries; the orange CPVC duct range sits alongside the pressure pipe.
Water treatment & desalination
Brine, antiscalant and cleaning-chemical lines where both temperature and chemical aggression are present at once.
Jointing & installation
- Solvent cementCPVC cement and primer only. The joint is chemical weld; cure time before pressure test is longer than for PVC-U, especially at low ambient
- ThreadedSCH 80 wall takes a thread directly, which is why CPVC is common on small-bore chemical lines and pump connections
- FlangedStub flange with backing ring at equipment; bolt torque rechecked after the first thermal cycle
- ExpansionAllow for thermal movement — expansion loops or offsets on long hot runs, and hangers that do not clamp the pipe rigid